T-T Electric  >  Products  >  DC Motors  >  DMP   > Application data - General

Standards
   • IEC 34 - IEC 72

Insulation
   • Class H

Balance
   • IEC 34-14 grade 'N' standard
   • Grade 'R' on request

Temperature rise
   • Class F

Overload capacity
   • 1.8 x FLC for 15 seconds every 5 minutes
   • 1.8 x FLC for 30 seconds every 30 minutes

Terminal box position
   • Standard: On top of the motor
   • Mounting of terminal box on either side on request

Blower position
   • Standard: On top of the motor non-drive end
   • Other positions on request

   • Blower is supplied without filter as standard
   • Filter on request

Bearings
   • Grease lubricated ball bearings as standard
   • For belt drive please contact our sales offices

Heat exchangers - Air/water (IC 86W):
   • Air/water exchangers are especially recommended for polluted environment
   • Standard is for clean water
   • For corrosive water on request

   • Position on top of motor as standard
   • Fan motor at D-end
   • Water connection flanges at right hand side (facing D-end)
   • Max water pressure 10 PSI
   • Max inlet water temperature 25°C
   • A water temperature rise of 8-10°C must be expected

   • For motors with low loads or a low incoming water temperature, a temperature regulator a temperature regulator is recommended to avoid condensation in the cooling air cicuit and to minimize water consumption
   • A constant speed fan ciculates the internal cooling air. A polyamide filter is provided for carbon dust

Heat exchangers - Air/air (IC 666):
   • Air/air exchangers are recommended where water is not available for cooling purposes
   • The output of a motor with air/air exchanger will be approximately 20% lower compared to cooling forms IC06/17/37/86W



T-T Electric  >  Products  >  DC Motors  >  DMP   > Application data - Blower motor data

Frame Supply voltage, frequency Y (V) Current Y (A) Supply voltage, frequency D (V) Current D (A) Power (kW) Weight (kg)
DMP 112
DMP 132-2M
DMP 132-4S/M/L
3x380-420V 50Hz
3x440-480V 60Hz
3x500V 50Hz
0.70
0.70
0.60
3x220-240V 50Hz
3x250-280V 60Hz
 
1.20
1.20
 
0.25
0.30
0.25
7
 
 
DMP 132-4LB
DMP 160-4S/M/L
 
3x380-420V 50Hz
3x440-480V 60Hz
3x500V 50Hz
2.10
2.00
1.40
3x220-240V 50Hz
3x250-280V 60Hz
 
3.60
3.50
 
0.75
0.90
0.75
16
 
 
DMP 160-4LB
 
 
3x380-420V 50Hz
3x440-480V 60Hz
3x500V 50Hz
2.90
2.80
2.30
3x220-240V 50Hz
3x250-280V 60Hz
 
5.00
5.00
 
1.30
1.50
1.30
18
 
 
DMP 180-4A/B/C/D
 
 
3x380-420V 50Hz
3x440-480V 60Hz
3x500V 50Hz
3.00
2.90
2.70
3x220-240V 50Hz
3x250-280V 60Hz
 
5.20
5.00
 
1.50
1.75
1.50
18
 
 
DMP 180-4E/F
 
 
3x380-420V 50Hz
3x440-480V 60Hz
3x500V 50Hz
5.80
5.80
4.60
3x220-240V 50Hz
3x250-280V 60Hz
 
10.0
10.0
 
2.70
3.00
2.70
20
 
 


T-T Electric  >  Products  >  DC Motors  >  DMP   > Application data - Bearing types

Frame Drive End Non-drive End
Ball Bearing Roller Bearing Roller Bearing
DMP 112 6308-C3 NU 308 ECP 6208-2RS 1-HT-C3
DMP 132 6309-C3 NU 309 ECP 6307-2RS 1-HT-C3
DMP 160 6310-C3 NU 310 ECP 6309-2RS 1-HT-C3
DMP 180-4A/B/C/D/E 6215-C3 NU 2215 ECP 6312-2RS 1-HT-C3
DMP 180-4F 6315-C3 NU 315 ECP 6312-2RS 1-HT-C3


Previous page T-T Electric DMP catalogue Next page T-T Electric DMP catalogue Top of page T-T Electric DMP catalogue