Standards • IEC 34 - IEC 72 • VDE 0530 - BS 4999 |
|
Insulation • Class F |
|
Balance • IEC 34-14 grade N • Grade R on request |
|
Temperature Rise • Class F, 105oC by resistance |
|
Overload capacity • 1.6 x FLT for 15 seconds every 5 minutes • 2.0 x nominal armature current for 30 seconds every 15 minutes |
|
Terminal box position • Standard top mounting • Side mounting on request |
|
Blower position • LAK 2080 and 2100: On either side of the motor • LAK 2112 and 2132: On top or on either side of the motor |
|
Bearings • Sealed-for-life preloaded ball bearings |
|
Armature voltages • LAK 2080-2100: 470 V • LAK 2112-2132: 570 V |
| Frame | Inertia J - kgm2 |
Max. mechanical speed (min-1) |
| LAK 2080A LAK 2080B LAK 2080C |
0.0025 0.0029 0.0038 |
6500 6500 6500 |
| LAK 2100A LAK 2100B LAK 2100C |
0.0080 0.0105 0.0140 |
6000 6000 6000 |
| LAK 2112A LAK 2112B LAK 2112C |
0.0153 0.0223 0.0262 |
5500 5500 5500 |
| LAK 2112A LAK 2112B LAK 2112C |
0.0350 0.0414 0.0575 |
5000 4500 4500 |
| Frame | IC06/17/37 | IC416 | ||
| Air Volume m3/h |
Pressure drop in motor n/m2 |
Air Volume m3/h |
Pressure drop n/m2 |
|
| LAK 2080 LAK 2100 LAK 2112 LAK 2132 |
30 120 200 300 |
100 250 650 625 |
45 70 150 175 |
85 85 175 175 |
| Frame | IC06 | ||
| Blower Type |
Electric Supply | F.L.C.(A) | |
| LAK 2080 | I | 1x220-240V 50Hz | 0.18 |
| LAK 2100 | II/III | 1x220-240V 50Hz 1x220-240V 50Hz 3x380-420V 50-60Hz |
0.35 0.42 0.12 |
| LAK 2112 LAK 2132 |
V | 3x380-420V 50Hz 3x440-500V 60Hz |
0.65 0.65 |
| Frame | IC416 | ||
| Blower Type |
Electric Supply | F.L.C.(A) | |
| LAK 2080 | I | 1x220-240V 50Hz | 0.18 |
| LAK 2100 LAK 2112 LAK 2132 |
II/III | 1x220-240V 50Hz 1x220-240V 50Hz 3x380-420V 50-60Hz |
0.35 0.42 0.12 |
![]() |
![]() |
![]() |