T-T Electric  >  Products  >  DC Motors  >  LAKC 4/6000   > Application data - General

Standards
   • IEC 34 - IEC 72

Insulation
   • Class H (180°C)

Balance
   • IEC 34-14 grade 'N' standard
   • Reduced vibration levels on request

Temperature rise
   • Class F (155°C)

Overload capacity
   • 1.6 x FLT for 15 seconds every 5 minutes
   • 2.0 x FLC for 30 seconds every 30 minutes
   • 2.0 x FLC - 1.9 x FLT at rated flux
   • Overloads must be followed by periods of reduced loading in order to maintain an r.m.s. load cycle of 1.0 x FLC
   • Other duty cycles available on request

Dynamic loading
   • Suitable for di/dt of 200 x FLC/sec
   • 2.0 x FLC for 30 seconds every 30 minutes
   • Higher levels considered on request

Standstill
The permissable currents during standstill operation with the cooling air applied are:
   • 2.0 x FLC for 10 seconds
   • 1.0 x FLC for 30 seconds

   • 0.5 x FLC for 90 seconds
   • 0.2 x FLC for 300 seconds
   • 0.15 x FLC for 600 seconds

Terminal box position
   • Right hand side viewed from d-end
   • Left hand side or top mounting available on request

Blower position
   • Top mounted at d-end
   • Other positions available on request

Filter
   • Filter available on request

Bearings
   • Grease lubricated ball bearings suitable for direct drive
   • For belt drive or side loading, please contact our sales offices

Heat exchangers - Air/water (IC 86W):
   • Air/water exchangers are especially recommended for polluted environment
   • Standard is for clean water
   • For corrosive water on request

   Mounting:
   • Position on top of motor as standard
   • Other positions and for remote loading, please contact our sales offices

   Water inlet/outlet:
   • DIN2566 - PN16
   • Other connection forms available on request
   • Water connections are on the opposite side to the terminal box
   • For other positions, please contact our sales offices

   Water parameters:
   • Inlet temperature maximum 25°C
   • Inlet pressure maximum 3,45 bars
   • Pressure drop maximum 35 kPa
   • A temperature rise of 8 to 10°C must be expected

Heat exchangers - Air/air (IC 666):
   • Air/air exchangers are recommended where water is not available for cooling purposes
   • The output of a motor with air/air exchanger will be approximately 20% and the speed will be increased by approximately 9% compared to cooling form IC06
   • Motor output data available on request

   Mounting:
   • Position on top of motor as standard
   • Other positions available on request
   • Two constant speed ac fan motors on the heat exchanger side provide air circulation for the external and internal circuits

Protection
Standard:
   • Water flow switch (IC86W)
   • Air pressure switch (IC666)
   • Internal air circuit filter
   • Air leakage replacement filter
   • Air pressure switch internal
The internal air pressure switch indicates air flow failure only, it does not react to a reduction in air flow due to contaminated filter

Options
   • Differential pressure switch across filter monitoring contamination
   • Water flow control valve for motors used continuously in a lightly loaded condition (IC86W)

Footnote
   • Detail heat exchanger information supplied upon request
   • For motors on light load or with low inlet water temperature, a temperature regulated water volume control valve is recommended to avoid condensation in the cooling air circuit, minimise water consumption and reduce the risk of too cold commutator running conditions



T-T Electric  >  Products  >  DC Motors  >  LAKC 4/6000   > Application data - Mechanical data

Frame Inertia
J - kgm2
Max. mechanical
speed (min-1)
LAKC 4355A
LAKC 4355B
LAKC 4355C
14.3
15.8
17.3
2500
2500
2500
LAKC 6400A
LAKC 6400B
LAKC 6400C
23.0
28.8
36.3
1800
1800
1800
LAKC 6500A
LAKC 6500B
LAKC 6500C
LAKC 6500D
69.5
87.1
109.8
127.0
1800
1800
1800
1800
LAKC 6560A
LAKC 6560B
LAKC 6560C
LAKC 6560D
145.0
165.0
187.5
207.5
1200
1200
1200
1200

Commutator codes 7 and 8 available on request


T-T Electric  >  Products  >  DC Motors  >  LAKC 4/6000   > Application data - Cooling data

Frame Air volume
m3/h
Pressure drop in
motor N/m2
LAKC 4355 7200 1670
LAKC 6400 12600 1470
LAKC 6500 18000 1520
LAKC 6560 21600 1860


T-T Electric  >  Products  >  DC Motors  >  LAKC 4/6000   > Application data - Blower motor data

Voltage supply : 3 x 380 - 420V (+/-5%),50 Hz

Frame KW FKC(A)
LAKC 4355 5.5 11.9
LAKC 6400 11.0 23.0
LAKC 6500 11.0 23.0
LAKC 6560 18.5 39


T-T Electric  >  Products  >  DC Motors  >  LAKC 4/6000   > Application data - Bearing types

Frame Commutator End Drive End
LAKC 4355 6228 C3 6228 C3
LAKC 6400 6230 C3 6230 C3
LAKC 6500 6232 C3 6234 C3
LAKC 6560 6232 C3 6244 C3


Previous page T-T Electric LAKC 4/6000 catalogue Next page T-T Electric LAKC 4/6000 catalogue Top of page T-T Electric LAKC 4/6000 catalogue